<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی حداکثر ظرفیت هوازی (VO2max) و عوامل مرتبط با آن در آتش‌نشانان</title_fa>
	<title>Investigation of Maximal Aerobic Capacity and Associated Factors in Firefighters</title>
	<subject_fa>ارگونومی</subject_fa>
	<subject>Ergonomics</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p align=&quot;right&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; حداکثر میزان اکسیژن مصرفی افراد نمودی بارز از توانایی انجام کار جسمانی در آنهاست. بدین ترتیب، در مشاغل با نیازهای فیزیکی سنگین مانند آتش&#8204;نشانی، ارزیابی&#8204;های دقیق ظرفیت هوازی کارکنان برای اطمینان از توانایی جسمانی و متناسب بودن آنان با شغل خود ضروری است. این پژوهش با هدف بررسی حداکثر ظرفیت هوازی و عوامل مرتبط با آن در آتش&#8204;نشانان انجام شده است.&lt;/p&gt;

&lt;p align=&quot;right&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در این مطالعه&#8204; توصیفی تحلیلی مقطعی، 31 نفر از کارکنان عملیاتی آتش&#8204;نشانی تهران به صورت تصادفی ساده از ایستگاه&#8204;های آتش&#8204;نشانی مستقر در شهر تهران انتخاب شدند و پرسشنامه&#8204; اطلاعات دموگرافیک- شغلی و آزمون تست پله &#8204;توکسورث و شهنواز بکار برده شد. برای تحلیل داده&#8204;ها، از نرم&#8204;افزار SPSS19و روش&#8204;های آماری توصیفی و استنباطی استفاده شد.&lt;/p&gt;

&lt;p align=&quot;right&quot;&gt;&lt;/p&gt;

&lt;p align=&quot;right&quot;&gt;&amp;nbsp;&lt;strong&gt;یافته ها:&lt;/strong&gt; میانگین حداکثر اکسیژن مصرفی در آتش&#8204;نشانان مورد بررسی ml/kg/min 28/3&amp;plusmn; 18/36 بود. حداکثر ظرفیت هوازی با وزن همبستگی معکوس معنادار داشت (43/0-= r، 017/0= P) اما ارتباط بارزی بین وضعیت تأهل، داشتن شغل دوم، داشتن سابقه&#8204; استعمال دخانیات، قد، گروه سنی، شاخص توده&#8204; بدنی و سمت در بخش عملیاتی با حداکثر ظرفیت هوازی در سطح 5 درصد وجود نداشت.&lt;/p&gt;

&lt;p align=&quot;right&quot;&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; حداکثر ظرفیت هوازی آتش&#8204;نشانان در مطالعه&#8204; حاضر بر اساس مقادیر معیار حداکثر ظرفیت هوازی در طبقه متوسط (برای گروه سنی 29-20 سال، در محدوده ml/kg/min 42-34، برای گروه سنی 39- 30 در محدوده ml/kg/min 38- 31 و برای گروه سنی 49- 40 در محدوده ml/kg/min 35-27) قرار دارد و از مقادیر گزارش شده در بسیاری از گروه&#8204;های شغلی دیگر بالاتر بوده، ولی در مقایسه با نتایج مطالعات انجام شده بر آتش&#8204;نشانان در سطح جهان کمتر بود؛ از این&#8204;رو توجه اکید بر افزایش توان هوازی آنان با توجه به اهمیت شغل آتش&#8204;نشانی توصیه می&#8204;گردد. همچنین، انجام مطالعات مشابه با دیگر روش&#8204;های سنجش حداکثر ظرفیت هوازی نظیر استفاده از تردمیل و دوچرخه و مقایسه نتایج با تست پله پیشنهاد می&#8204;گردد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&amp;nbsp;&lt;strong&gt; Background and aims: &lt;/strong&gt;Maximal oxygen uptake (VO&lt;sub&gt;2&lt;/sub&gt;max) represents physical work capacity. Therefore in physically demanding jobs like firefighting, precise evaluation of employees&amp;#39; aerobic capacity is critical in order to ensure their physical capabilities and fitness for work duties. The aim of this study was to evaluate the maximal aerobic capacity and its associated factors in firefighters.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;strong&gt; Methods: &lt;/strong&gt;In this cross-sectional, descriptive, analytical study, 31 firefighters from suppression division of Tehran Fire Department were selected randomly. Socio-demographic questionnaire and also Tuxworth and Shahnavaz step test method were applied as research tools. Data were analyzed using descriptive and inferential statistics via SPSS19 software.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;strong&gt; Results: &lt;/strong&gt;The obtained results showed that the mean VO&lt;sub&gt;2&lt;/sub&gt;max in firefighters was 36.18 &amp;plusmn; 3.28 ml/kg/min. VO&lt;sub&gt;2&lt;/sub&gt;max had a significant negative correlation with weight ( P=0.017, r= -0.43 ). There was no significant relationship between VO&lt;sub&gt;2&lt;/sub&gt;max and marital status, having another job, smoking status , height, age group, BMI, and job title (&amp;alpha;= 0.05).&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;strong&gt; Conclusion: &lt;/strong&gt;The mean value of VO&lt;sub&gt;2&lt;/sub&gt;max in firefighters was determined to be at average level according to its norm values (34- 42 ml/kg/min for age group of 20- 29 years old, 31- 38 ml/kg/min for 30- 39 years old and 27- 35 ml/kg/min for 40- 49 years old), and higher than the other job groups&amp;#39; reported values in other studies but, in comparison with firefighters of other countries, their VO&lt;sub&gt;2&lt;/sub&gt;max was less. Due to the importance of firefighters&amp;#39; job and according to the results of our study, making effort to enhance firefighters&amp;#39; VO&lt;sub&gt;2&lt;/sub&gt;max is really important. In addition, conducting similar research using other methods for evaluating VO&lt;sub&gt;2&lt;/sub&gt;max such as treadmill and ergo cycle is suggested.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>حداکثر ظرفیت هوازی, آتش نشانان, ویژگی های دموگرافیک.</keyword_fa>
	<keyword> Maximal Aerobic Capacity (VO2max), Firefighters, Demographic variables.</keyword>
	<start_page>15</start_page>
	<end_page>26</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-1024-4&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Firoozeh</last_name>
	<suffix></suffix>
	<first_name_fa>مرجان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فیروزه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.firoozeh@gmail.com</email>
	<code>13600319475328460030846</code>
	<orcid>13600319475328460030846</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>HSE faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>دانشکده سلامت، ایمنی و محیط زیست، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Saremi</last_name>
	<suffix></suffix>
	<first_name_fa>مهناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صارمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>saremim@yahoo.com</email>
	<code>13600319475328460030847</code>
	<orcid>13600319475328460030847</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>HSE faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>دانشکده سلامت، ایمنی و محیط زیست، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>Maleki</last_name>
	<suffix></suffix>
	<first_name_fa>اعظم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ملکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>azam.maleki13@gmail.com</email>
	<code>13600319475328460030848</code>
	<orcid>13600319475328460030848</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>HSE faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>دانشکده سلامت، ایمنی و محیط زیست، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>Kavousi</last_name>
	<suffix></suffix>
	<first_name_fa>امیر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاوسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kavousi_am@yahoo.com</email>
	<code>13600319475328460030849</code>
	<orcid>13600319475328460030849</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>HSE faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>دانشکده سلامت، ایمنی و محیط زیست، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
