<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>واکاوی پیامدهای آتش‌سوزی و انفجار مخازن استوانه‌ای ذخیره گاز مایع در یک صنعت منتخب نفت و گاز </title_fa>
	<title> Consequence Analysis of fire and explosion of a cylindrical LPG tank in a selected industry of oil and gas </title>
	<subject_fa>ایمنی فرآیند</subject_fa>
	<subject>Process Safety</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;زمینه و هدف: &lt;/strong&gt;با توجه به حوادث رخ&#8204;داده در اثر نشت گاز مایع &lt;span dir=&quot;LTR&quot;&gt;(LPG)&lt;/span&gt;، موضوع واکاوی پیامد آتش&#8204;سوزی و انفجار مخازن ذخیره حاوی این ماده از اهمیت زیادی برخوردار است. هدف از مطالعه حاضر واکاوی پیامدهای آتش&#8204;سوزی و انفجار یک مخزن استوانه&#8204;ای ذخیره &lt;span dir=&quot;LTR&quot;&gt;LPG&lt;/span&gt; در یک صنعت منتخب نفت و گاز است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;روش بررسی: &lt;/strong&gt;در این مطالعه تحلیلی، چهار سناریوی نقص، شامل گسیختگی یک مخزن استوانه&#8204;ای ذخیره &lt;span dir=&quot;LTR&quot;&gt;LPG&lt;/span&gt;، نشتی مخزن از محل لوله ورودی، نشتی مخزن از محل دریچه آدم&#8204;رو و باز شدن شیر ایمنی و پیامدهای آتش&#8204;سوزی و انفجار متناظر با آن&#8204;ها توسط نرم&#8204;افزار &lt;span dir=&quot;LTR&quot;&gt;PHAST&lt;/span&gt; شبیه&#8204;سازی شد. سپس نتایج به&#8204;دست آمده با معیارهای موجود مقایسه شد و شدت آسیب&#8204;رسانی پیامدها مشخص گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته&#8204;ها: &lt;/strong&gt;با توجه به نتایج به&#8204;دست آمده، ناحیه اثر آتش کروی ناشی از سناریوی گسیختگی مخزن با شدت تشعشع &amp;nbsp;5/37 تا شعاع 290 متر از محل مخزن است که با توجه به خطوط راهنما، در این میزان شدت تابش، احتمال آسیب عمده به تجهیزات فرآیندی، تخریب سازه&#8204;ها و مرگ&#8204;ومیر قطعی افراد حاضر در این ناحیه وجود دارد. در پیامد آتش ناگهانی این سناریو، در محدوده&#8204;ای به شعاع 505 متر احتمال مرگ&#8204;ومیر افراد صددرصد است. در پیامد انفجار ناشی از گسیختگی مخزن، موج انفجار &lt;span dir=&quot;LTR&quot;&gt;bar&lt;/span&gt; 2/0 تا شعاع 2092 متری قابل مشاهده است. سناریوی نشتی از محل دریچه آدم&#8204;رو نیز شامل پیامدهای آتش فورانی، انفجار و آتش ناگهانی است. هم&#8204;چنین سناریوهای نشتی از محل لوله ورودی و باز شدن شیر ایمنی، پیامدهای آتش فورانی و آتش ناگهانی را به دنبال خواهد داشت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری: &lt;/strong&gt;با توجه به شدت پیامدهای سناریوی اول و احتمال رخ دادن حوادث زنجیره&#8204;ای در تأسیسات ذخیره گاز مایع، پیشنهاد می&#8204;شود به&#8204;جای مخازن استوانه&#8204;ای افقی از مخازن کروی استفاده شود و هم&#8204;چنین برنامه جامع واکنش در شرایط اضطراری در اولویت&#8204;های نخست واحد ایمنی قرار گیرد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;کلیدواژه&#8204;ها: &lt;/strong&gt;واکاوی پیامد، آتش&#8204;سوزی، انفجار، مخازن &lt;span dir=&quot;LTR&quot;&gt;LPG&lt;/span&gt;، &lt;span dir=&quot;LTR&quot;&gt;PHAST&lt;/span&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and aims:&lt;/strong&gt; Accidents happened as a result of LPG leakage emphasizes the&amp;nbsp;importance&amp;nbsp;of the consequence analysis of fire and explosion in LPG storage tanks. The purpose of this study is to analysis the consequences of fire and explosion in a cylindrical LPG storage tank in an oil and gas industry.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Method:&lt;/strong&gt; In this analytical study, four possible failure scenarios including 1) rupture in the cylindrical LPG tank 2) leakage from the loading line 3) leakage from the tank manhole and 4) undesirable opening of the safety valve, and their fire and explosion consequences were simulated by PHAST software. Then the results were compared with existing standards&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The scenario of tank rupture leads to a&amp;nbsp;radiation&amp;nbsp;flux 37.5 kw/m&lt;sup&gt;2&lt;/sup&gt; affect&amp;nbsp;a radius of 290 m from tank location that can cause major life and property losses. As the result of a flash fire due to the tanker rupture, there is a possibility of life-threatening to a radius of 520 m. An explosion (resulting from the tank rupture) with&amp;nbsp;blast&amp;nbsp;wave of 0.2 bar affect&amp;nbsp;a radius of 2092 m that can cause the life and property losses. The scenario of leakage from the tank manhole leads to jet fire, explosion and flash fire. Also, the jet fire and flash fire will follow by the scenarios of leakage from the loading and undesirable opening of the safety valve.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; With attention to severity the tank rupture and the likelihood of&amp;nbsp;occurrence&amp;nbsp;of the&amp;nbsp;domino&amp;nbsp;effect, it is recommended to substitute the horizontal cylindrical LPG tanks by the spherical ones. Also, an emergency response plan should be established based on the result of this study.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Keywords: &lt;/strong&gt;Consequence Analysis, Fire, Explosion, LPG Tank, PHAST&lt;/p&gt;
</abstract>
	<keyword_fa>واکاوی پیامد, آتش‌سوزی, انفجار, مخازن PHAST, LPG                                                                                              </keyword_fa>
	<keyword>Consequence Analysis, Fire, Explosion, LPG Tank, PHAST </keyword>
	<start_page>37</start_page>
	<end_page>45</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-1715-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hamid </first_name>
	<middle_name></middle_name>
	<last_name>Kariznovi</last_name>
	<suffix></suffix>
	<first_name_fa>حمید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاریزنوی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hkariznovi68@gmail.com</email>
	<code>13600319475328460026790</code>
	<orcid>13600319475328460026790</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی بهداشت حرفهای، دانشگاه علوم پزشکی ایران، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali Asghar </first_name>
	<middle_name></middle_name>
	<last_name>Farshad</last_name>
	<suffix></suffix>
	<first_name_fa>علی اصغر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فرشاد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fdgir@yahoo.com</email>
	<code>13600319475328460026791</code>
	<orcid>13600319475328460026791</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات بهداشت کار، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Rasoul </first_name>
	<middle_name></middle_name>
	<last_name>Yarahmadi</last_name>
	<suffix></suffix>
	<first_name_fa>رسول</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاراحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yarahmadi.r@iums.ac.ir</email>
	<code>13600319475328460026792</code>
	<orcid>13600319475328460026792</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات آلودگی هوا ،دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Yahya </first_name>
	<middle_name></middle_name>
	<last_name>Khosravi</last_name>
	<suffix></suffix>
	<first_name_fa>یحیی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خسروی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>YAKHOSRAVI@yahoo.com</email>
	<code>13600319475328460026793</code>
	<orcid>13600319475328460026793</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>مرکز تحقیقات بهداشت، ایمنی و محیط زیست دانشگاه علوم پزشکی البرز، کرج، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Peyman </first_name>
	<middle_name></middle_name>
	<last_name>Yari</last_name>
	<suffix></suffix>
	<first_name_fa>پیمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yari.1989@yahoo.com</email>
	<code>13600319475328460026794</code>
	<orcid>13600319475328460026794</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>کارشناس ارشد مهندسی بهداشت حرفهای، دانشگاه علوم پزشکی ایران، تهران، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
