<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>اعتبار سنجی مدل شبیه سازی الگوی جریان هوا در اتاق های پاک(مطالعه موردی در صنایع دارویی 1394)</title_fa>
	<title>Validation of model simulations of air flow in cleanrooms (Case Study in the pharmaceutical industry at 2015)</title>
	<subject_fa>پایش آلودگی هوا</subject_fa>
	<subject>Air pollution monitoring</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مقدمه&lt;/strong&gt;: در اتاق پاک &amp;nbsp;غلظت ذرات هوابرد تحت کنترل می&#8204;باشد و نقش مهمی در تولید داروها و محصولات با تکنولوژی بالا &amp;nbsp;دارد&lt;span dir=&quot;LTR&quot;&gt;.&lt;/span&gt; الگوی جریان هوا یکی از پارامترهای مهم و موثر در غلظت ذرات و توزیع آلودگی درون اتاق های پاک می باشد، بنابراین الگوسازی دقیق جریان هوا درون اتاق های پاک حائز اهمیت می باشد. بنابراین در این مطالعه ارزیابی و شبیه سازی الگوی جریان هوا در اتاق های پاک مورد بررسی قرار گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&amp;nbsp;&lt;strong&gt;روش بررسی&lt;/strong&gt; : مطالعه حاضر یک پژوهش تجربی-کاربردی می باشد که در سال 1394 در یک صنعت دارویی انجام شد. روش انجام کار در این مطالعه بررسی تعیین &amp;nbsp;الگوی جریان هوا در اتاق پاک &amp;nbsp;می باشد. در این مطالعه 3 اتاق پاک مربوط به 3 کلاس پاکیزگی &lt;span dir=&quot;LTR&quot;&gt;B &lt;/span&gt;&amp;nbsp;&amp;nbsp;، &lt;span dir=&quot;LTR&quot;&gt;C&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;D &lt;/span&gt;&amp;nbsp;&amp;nbsp;مورد بررسی قرار گرفت . سپس شبیه سازی الگوی جریان، تعیین بردارهای سرعت در اتاق پاک&amp;nbsp; توسط تکنیک &lt;span dir=&quot;LTR&quot;&gt;CFD&lt;/span&gt; می باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته ها :&lt;/strong&gt; یافته های این مطالعه نشان داد که&amp;nbsp; سرعت جریان هوا اندازه گیری شده در مدل تجربی ، در فواصل افقی و عمودی مختلف با سرعت های جریان هوا &amp;nbsp;پیش بینی شده توسط نرم افزار فلوئنت در شرایط مشابه و در فواصل یکسان &amp;nbsp;بسیار نزدیک به هم&amp;nbsp; می باشد. هم چنین کانتورهای سرعت جریان هوا برای 3 کلاس پاکیزگی تعیین گردید. &amp;nbsp;بعلاوه، نتایج سنجش غلظت ذرات در اتاق های &amp;nbsp;پاک&amp;nbsp; نشان می دهد که میانگین تراکم آلودگی ذرات در سه کلاس پاکیزگی از حد مجاز&amp;nbsp; استاندارد&amp;nbsp; پایین تر بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه گیری&lt;/strong&gt; : &amp;nbsp;این مطالعه نشان داد که مدل آشفتگی &lt;span dir=&quot;LTR&quot;&gt;RNG K-&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;ℇ&lt;/span&gt; &amp;nbsp;مناسب ترین مدل برای شبیه سازی الگوی جریان هوا در اتاق پاک می باشد . هم چنین وجود ابزار وتجهیزات موجود در اتاق پاک بر الگوی جریان هوا و در نهایت بر راندمان حذف ذرات در اتاق پاک تاثیر می گذارد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and aims&lt;/strong&gt;: The clean room is under the control of concentrations of airborne particles play an important role in the production of drugs and high-tech products. Clean air flow pattern in the room is one of the important parameters of particle concentration and distribution of air pollution and need to be accurately modeled. So in this study was to evaluate and simulate the flow pattern of clean air in the room was investigated&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Methods&lt;/strong&gt;: This study used an experimental study that was conducted at 2015 in the pharmaceutical industry .The methodology used in this study was to determine the air flow pattern in cleanroom. In this study, 3 clean room with 3 cleanliness classes B, C and D were studied. Then simulate the flow pattern, determine the velocity vectors in the cleanroom is cleared by CFD techniques&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The findings of this study showed that air flow rate measured in experimental models with air flow rates predicted by FLUENT software under the same conditions and at the same spacing is very close to each other .Also airflow velocity contours for 3 the cleanliness class were determined&amp;nbsp;&lt;span dir=&quot;RTL&quot;&gt; &amp;nbsp;.&lt;/span&gt;In addition, the results of measurement of particle concentration in clean rooms shows the mean concentration of particulate contamination in three classes cleanliness was below the standard limit.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;: This study showed that RNG K-ℇ turbulence model the most appropriate model to simulate air flow pattern in the room is clean. There is also equipment and a tool in a clean room on the pattern of air flow and ultimately affects the particle removal efficiency in the clean room&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>مدل آشفتگی RNG K-ℇ, شبیه سازی, جریان هوا, فلوئنت</keyword_fa>
	<keyword>RNG k–ε turbulence model, simulation, Airflow, fluent</keyword>
	<start_page>34</start_page>
	<end_page>25</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-1705-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Zabiolah</first_name>
	<middle_name></middle_name>
	<last_name>Damiri</last_name>
	<suffix></suffix>
	<first_name_fa>ذبیح اله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دمیری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Zabiolah.damiri@gmail.com</email>
	<code>13600319475328460026854</code>
	<orcid>13600319475328460026854</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>faculty of public health, iran university of medical sciences, tehran, iran</affiliation>
	<affiliation_fa>دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Rasoul</first_name>
	<middle_name></middle_name>
	<last_name>Yarahmadi</last_name>
	<suffix></suffix>
	<first_name_fa>رسول</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاراحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Yarahmadi.r@iums.ac.ir</email>
	<code>13600319475328460026855</code>
	<orcid>13600319475328460026855</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Air Pollution Research Center, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات آلودگی هوا، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mitra</first_name>
	<middle_name></middle_name>
	<last_name>Rashidi</last_name>
	<suffix></suffix>
	<first_name_fa>میترا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رشیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rashidi.mitra02@gmail.com</email>
	<code>13600319475328460026856</code>
	<orcid>13600319475328460026856</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>faculty of health, tehran university of medical sciences, tehran, iran</affiliation>
	<affiliation_fa>دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
