<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>نمونه برداری و تعیین مقدار کلروبنزن در هوا با روش  میکرواستخراج فاز جامد-گاز کروماتوگرافی طیف بین جرمی </title_fa>
	<title>Sampling and quantification of chlorobenzene in air by solid phase microextraction-gas chromatography mass spectrometry </title>
	<subject_fa>عوامل شیمیایی محیط کار</subject_fa>
	<subject>Chemical agents at work</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;چکیده&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; کلروبنزن ماده&#8204;ای شیمیای است که در تولید حشره&#8204;کش&#8204;ها، علف&#8204;کش&#8204;ها و همچنین تولید لاستیک استفاده می&#8204;شود و باعث عوارض نرولوژیکی و اثر بر مجاری تنفسی می&#8204;گردد. در این پژوهش با استفاده از روش میکرواستخراج فاز جامد (&lt;span dir=&quot;LTR&quot;&gt;(SPME&lt;/span&gt;&amp;nbsp; مقدار کلروبنزن در هوای محیط کار نمونه&#8204;برداری و شرایط بهینه&#8204;ی تجزیه با گازکروماتوگرافی-طیف&#8204;بین جرمی تعیین گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; نمونه&#8204;برداری از غلظت های مشخص کلروبنزن در یک سیستم تولید اتمسفر دینامیک با روش میکرواستخراج فاز جامد انجام گرفت. پس از انتخاب نوع فیبرهای لازم، دما و زمان بازیافت بهینه در بخش تزریق تعیین شد و نتایج بدست آمده از &lt;span dir=&quot;LTR&quot;&gt;SPME&lt;/span&gt; با روش شماره&#8204;ی 1003، انستیتوی ملی ایمنی و بهداشت حرفه&#8204;ای مقایسه گردید. به&#8204;منظور تجزیه&#8204;ی نمونه&#8204;های تهیه&#8204;شده از کلروبنزن با روش میکرواستخراج فاز جامد (&lt;span dir=&quot;LTR&quot;&gt;SPME&lt;/span&gt;)، از دستگاه گازکروماتوگرافی-طیف&#8204;بین جرمی (MS&lt;span dir=&quot;LTR&quot;&gt;(GC-&lt;/span&gt;&amp;nbsp;استفاده گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته&#8204;ها:&lt;/strong&gt; نتایج نشان داد فیبر &lt;span dir=&quot;LTR&quot;&gt;CAR/PDMS&lt;/span&gt; از قابلیت جذب بیشتری درمقایسه&#8204;با سایر فیبرها برخوردار است. شرایط دمایی واجذب در بخش تزریق دستگاه آنالیز در سه حالت دمایی 200 تا 280 بررسی گردید و تفاوتی در مقدار استخراج کلروبنزن در این شرایط وجود نداشت (&lt;span dir=&quot;LTR&quot;&gt;P&gt;0.05&lt;/span&gt;). زمان تعادل برای حالت &lt;span dir=&quot;LTR&quot;&gt;SPME&lt;/span&gt; خارج از سرپوش، 30 دقیقه &amp;nbsp;و برای شرایط داخل سرپوش زمان رسیدن به تعادل تا چندین ساعت ادامه یافت. تفاوت معناداری در نرخ نمونه&#8204;برداری در دماها و سرعت&#8204;های تعیین&#8204;شده در این مطالعه وجود نداشت(&lt;span dir=&quot;LTR&quot;&gt;P&gt;0.05&lt;/span&gt;). هرچند افزایش رطوبت نسبی باعث کاهش نرخ نمونه&#8204;برداری در دامنه مورد بررسی گردید (&lt;span dir=&quot;LTR&quot;&gt;P&lt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;0.05&lt;/span&gt;).&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه&#8204;گیری&lt;/strong&gt;: در این پژوهش مشخص گردید که روش &lt;span dir=&quot;LTR&quot;&gt;SPME&lt;/span&gt; در سوزن میتواند به عنوان جایگزین مناسبی برای روش معمول &lt;span dir=&quot;LTR&quot;&gt;NIOSH&lt;/span&gt; &amp;nbsp;برای تعیین کلروبنزن در هوا مورد استفاده قرار گیرد. با استفاده از فیبر &lt;span dir=&quot;LTR&quot;&gt;SPME&lt;/span&gt; به صورت در سرپوش میتوان میانگین مواجهه&#8204;ی وزنی-زمانی &lt;span dir=&quot;LTR&quot;&gt;(TWA)&lt;/span&gt; در هوای محیط کار را به روش پسیو تعیین نمود&lt;/p&gt;
&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;div&gt;&amp;nbsp;
&lt;hr align=&quot;left&quot; size=&quot;1&quot; width=&quot;33%&quot; &gt;
&lt;div id=&quot;ftn1&quot;&gt;&lt;p align=&quot;left&quot;&gt;&lt;/p&gt;&lt;/div&gt;

&lt;div id=&quot;ftn2&quot;&gt;&lt;p align=&quot;left&quot;&gt;&lt;/p&gt;&lt;/div&gt;
&lt;/div&gt;
</abstract_fa>
	<abstract>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: left;&quot;&gt;&lt;strong&gt;&lt;span dir=&quot;LTR&quot;&gt;Abstract&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Background and aims&lt;/strong&gt;: The chlorobenzene is an intermediate chemical that is used in the production of commodities such as herbicides, dyestuffs, and rubber and Causes neurological complications and effects on the respiratory tract. In this research solid phase micro extraction (SPME) was used for the sampling of chlorobenzene in air. The optimum conditions for analysis with gas chromatography-Mass spectrometry (GC-MS) were determined&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Methods&lt;/strong&gt;: The sampling of chlorobenzene was done in a dynamic atmosphere generation system with SPME. The kind of fiber was selected and the optimum temperature and desorption time in injection port of GC were determined and results of measurement were compared with the NIOSH-1003 method. Samples were analyzed by gas chromatography-Mass spectrometry.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; Carboxen-Polydimethylsiloxane (CAR/PDMS) in retracted mode has high absorption compared to other fibers and was selected for sampling. Desorption temperature in the injector of GC were also optimized in three levels from 200 to 280 and results showed no significant difference were observed for extraction of analyte from SPME (P&gt;0.05).The equilibrium time at exposed condition in SPME was 30 minute but equilibrium time is extended for several hours in retracted mode. There were no significant differences between sampling rates at different temperatures and air velocities (P&gt;0.05) but, the increase of relative humidity (RH) had a negative effect on sampling rates (P&lt;0.05).&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;: &amp;nbsp;It is concluded that SPME in retracted mode is an alternative method for determination of chlorobenzene in air and could be applied as a passive method for the determination of the time weight average (TWA) of chlorobenzene in workplaces.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>روش میکرواستخراج فاز جامد, هوا, روش غیرفعال, کلروبنزن</keyword_fa>
	<keyword>SPME, Chlorobenzene, Air, Passive sampling</keyword>
	<start_page>52</start_page>
	<end_page>43</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-1500-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohamad javad</first_name>
	<middle_name></middle_name>
	<last_name>Zare Sakhvidi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد جواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زارع سخویدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mjzs63@gmail.com</email>
	<code>13600319475328460026860</code>
	<orcid>13600319475328460026860</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>, Yazd University of Medical Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی یزد</affiliation_fa>
	 </author>


	<author>
	<first_name>Abdulrahman</first_name>
	<middle_name></middle_name>
	<last_name>Bahrami</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالرحمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهرامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bahrami@umsha.ac.ir</email>
	<code>13600319475328460026861</code>
	<orcid>13600319475328460026861</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Hamadan University of Medical Sciences</affiliation>
	<affiliation_fa>علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali Reza</first_name>
	<middle_name></middle_name>
	<last_name>Ghiasvand</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>غیاثوند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a_ghiasvand@yahoo.com</email>
	<code>13600319475328460026862</code>
	<orcid>13600319475328460026862</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Lorestan University</affiliation>
	<affiliation_fa>دانشکاه لرستان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
