<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>14</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی و توسعه یک حسگر الکتروشیمیایی اصلاح شده با پلیمر قالب مولکولی و نانولوله های کربنی به منظور ارزیابی مواجهات محیطی و شغلی با آفت کش دی‌کلران</title_fa>
	<title>Designing and Development of an Electrochemical Sensor Modified with Molecularly Imprinted Polymer and Carbon Nanotubes for Evaluation of Occupational and Environmental Exposures to Dicloran Pesticide </title>
	<subject_fa>روشهای نوین سم شناسی</subject_fa>
	<subject>New Methods of Toxicology</subject>
	<content_type_fa>Full Text</content_type_fa>
	<content_type>Full Text</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;زمینه و هدف:&lt;/strong&gt; آفت کش دی&#8204;کلران برای مهار رشد اسپور قارچ ها بر روی محصولات کشاورزی استفاده می شود. به دلیل کاربرد روزافزون آفت کش ها، امکان ارزیابی مواجهه های شغلی و محیطی توسط روش های تجزیه دقیق و معتبر، ضروری به نظر می رسد. این مطالعه با هدف طراحی حسگری با گزینش پذیری بالا برای تعیین مقدار دی کلران در نمونه های محیطی و بیولوژیکی انجام شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; نانولوله های کربنی و پلیمر قالب مولکولی &lt;span dir=&quot;LTR&quot;&gt;(MIP)&lt;/span&gt; به عنوان اصلاح کننده در ساختار حسگر مورد استفاده قرار گرفتند. ابتدا &lt;span dir=&quot;LTR&quot;&gt;MIP&lt;/span&gt; سنتز شده و در ساختار الکترود خمیر کربنی&lt;span dir=&quot;LTR&quot;&gt; (CP)&lt;/span&gt;به کار گرفته شد. ترکیب این الکترود (حسگر)، بهینه سازی شده و برای تعیین غلظت آنالیت استفاده گردید. در این مطالعه جهت تعیین مقدار دی&#8204;کلران از روش تجزیه الکتروشیمیایی با عنوان ولتامتری موج مربعی استفاده گردید. پارامترهای تأثیر گذار بر پاسخ حسگر مانند &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; استخراج، &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; آنالیز، غلظت الکترولیت و شرایط دستگاهی مانند فرکانس و دامنه موج مربعی با انجام آزمایشاتی انتخاب شدند و پاسخ حسگر برای تعیین مقدار دی کلران ثبت گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته ها:&lt;/strong&gt; طبق نتایج، حسگر مورد نظر توانایی تشخیص و گزینش پذیری بسیار بالایی داشت. بازه&lt;span dir=&quot;LTR&quot;&gt;&amp;lrm;&lt;/span&gt;ی خطی به دست آمده برای منحنی کالیبراسیون&lt;sup&gt;6-&lt;/sup&gt;10&amp;times;5 تا &lt;sup&gt;9-&lt;/sup&gt;10&amp;times;5 مولار و حد تشخیص روش &lt;sup&gt;10-&lt;/sup&gt;10&amp;times;8/4 مولار محاسبه گردید. نتایج هم&#8204;چنین حاکی از عدم تداخل سایر ترکیبات موجود در ماتریکس نمونه های ادرار، آب آشامیدنی و آب رودخانه بر روی پاسخ حسگر می باشد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; حسگر الکتروشیمیایی می تواند برای تعیین مقدار آنالیت ها در نمونه های مختلف با موفقیت و بدون نیاز به مرحله آماده سازی خاص و پیچیده ای استفاده شود.&lt;/p&gt;
&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background and aims:&lt;/strong&gt; Dicloran pesticide is used to inhibit the fungal spore germination for different crops. Due to the increasing application of pesticides, evaluating the occupational and environmental exposures by reliable and accurate analytical methods is necessary. This work was aimed to design the high selective sensor to determine the dicloran in biological and environmental samples.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Methods:&lt;/strong&gt; Multi-walls carbon nanotubes and a molecularly imprinted polymer (MIP) were used as modifiers in the senor composition. A dicloran MIP was synthesized and applied in the carbon paste electrode (CP). After optimizing the electrode composition, it was used to determine the concentration of analyte. Parameters affecting the sensor response, such as sample pH, electrolyte concentration and its pH, and the instrumental parameters of square wave voltammetry were selected following some experiments.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Results:&lt;/strong&gt; The MIP-CP electrode showed very high recognition ability for determining of dicloran in different matrices (tap water, river water, and urine). The obtained linear range was 1&amp;times;10&lt;sup&gt;-6&lt;/sup&gt; to 1&amp;times;10&lt;sup&gt;-9&lt;/sup&gt; mol L&lt;sup&gt;-1&lt;/sup&gt;. The detection limit was 4.8&amp;times;10&lt;sup&gt;-10&lt;/sup&gt; molL&lt;sup&gt;-1&lt;/sup&gt;. No interfering effects was seen due to the other compounds in matrix.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; Selective sensors can successfully used to determine the analyte of interest in different environmental and biological samples without special sample pretreatment before analysis.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>دی کلران, پلیمر قالب مولکولی, حسگر, پایش بیولوژیکی</keyword_fa>
	<keyword>Dicloran, Molecularly imprinted polymer, sensor, Biological monitoring</keyword>
	<start_page>1</start_page>
	<end_page>12</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-1298-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Monireh</first_name>
	<middle_name></middle_name>
	<last_name>Khadem</last_name>
	<suffix></suffix>
	<first_name_fa>منیره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خادم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>khadem@sina.tums.ac.ir</email>
	<code>13600319475328460026780</code>
	<orcid>13600319475328460026780</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Tehran University of Medical Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Farnoush</first_name>
	<middle_name></middle_name>
	<last_name>Faridbod</last_name>
	<suffix></suffix>
	<first_name_fa>فرنوش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فریدبد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>faridbodf@khayam.ut.ac.ir</email>
	<code>13600319475328460026781</code>
	<orcid>13600319475328460026781</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Tehran</affiliation>
	<affiliation_fa>دانشگاه تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Parviz</first_name>
	<middle_name></middle_name>
	<last_name>Norouzi</last_name>
	<suffix></suffix>
	<first_name_fa>پرویز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوروزی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>norouzi@khayam.ut.ac.ir</email>
	<code>13600319475328460026782</code>
	<orcid>13600319475328460026782</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Tehran</affiliation>
	<affiliation_fa>دانشگاه تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Abbas</first_name>
	<middle_name></middle_name>
	<last_name>Rahimi Foroushani</last_name>
	<suffix></suffix>
	<first_name_fa>عباس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحیمی فروشانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rahimifo@tums.ac.ir</email>
	<code>13600319475328460026783</code>
	<orcid>13600319475328460026783</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Tehran University of Medical Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Reza</first_name>
	<middle_name></middle_name>
	<last_name>Ganjali</last_name>
	<suffix></suffix>
	<first_name_fa>محمد رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گنجلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ganjali@khayam.ut.ac.ir</email>
	<code>13600319475328460026784</code>
	<orcid>13600319475328460026784</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Tehran</affiliation>
	<affiliation_fa>دانشگاه تهران</affiliation_fa>
	 </author>


	<author>
	<first_name></first_name>
	<middle_name></middle_name>
	<last_name></last_name>
	<suffix></suffix>
	<first_name_fa>سید جمال الدین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شاه طاهری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>shahtaheri@tums.ac.ir</email>
	<code>13600319475328460026785</code>
	<orcid>13600319475328460026785</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دکترای بهداشت حرفهای، استاد، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Rasoul</first_name>
	<middle_name></middle_name>
	<last_name>Yarahmadi</last_name>
	<suffix></suffix>
	<first_name_fa>رسول</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یاراحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yarahmadi.r@iums.ac.ir</email>
	<code>13600319475328460026786</code>
	<orcid>13600319475328460026786</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Iran University of Medical Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
