<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1388</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2010</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>6</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه کارایی منعقد کننده های پلی آلومینیوم کلراید و آلوم در حذف فلوراید از آب</title_fa>
	<title>Comparison the efficiency of alum and commercial poly aluminum chloride for fluoride removal from water</title>
	<subject_fa>بیماریهای تنفسی</subject_fa>
	<subject>Respiratory disease</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt; &lt;strong&gt; هدف &lt;/strong&gt;: فلوراید به طور طبیعی و همچنین از طریق پساب صنایع مختلف به محیط زیست منتشر می‌شوند . فلوراید موجود در آب آشامیدنی با توجه به غلظت آن و میزان کل جذب شده می‌تواند مفید یا مضر باشد. به دلیل سهولت اجرا، دسترسی آسان به منعقد‌کننده‌های آلوم و پلی آلومینیم و ارزانی آنها، روش انعقاد به عنوان روش منتخب برای حذف فلوراید از آب مد نظر قرار گرفت. هدف از این مطالعه مقایسه کارایی منعقد‌کننده‌های پلی آلومینیوم کلراید تجاری و آلوم درحذف فلوراید از آب می‌باشد. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; روش بررسی &lt;/strong&gt;: آزمایشات در مقیاس آزمایشگاهی و به وسیله دستگاه جار انجام شد. متغیرهای این پژوهش شامل pH ، دزاژ منعقد‌کننده مصرفی و غلظت فلوراید در شرایط تعریف شده مورد بررسی قرار گرفتند. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; یافته‌ها &lt;/strong&gt;: نتایج آزمایشات نشان می‌دهد که pH بهینه حذف فلوراید برای هر دو منعقد‌کننده برابر 4 بود. غلظت آلوم و پلی‌آلومینیم‌کلراید جهت حذف فلوراید به ترتیب 240 و 160 میلیگرم بر لیتر و بازده حذف برای هر دو منعقد‌کننده در pH و دزاژ منعقد‌کننده بهینه به ترتیب 2/84 و 84 درصد بود. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; نتیجه‌گیری &lt;/strong&gt;: با توجه به نتایج حاصل از این مطالعه می‌توان اظهار کرد که روش انعقاد روش مناسبی برای حذف فلوراید از آب می‌باشد و پلی‌آلومینیم تجاری در حذف فلوراید قابل رقابت با آلوم می‌باشد. &lt;strong&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;  &lt;/p&gt;</abstract_fa>
	<abstract>&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p&gt;&lt;strong&gt;Background and aims&lt;/strong&gt;&lt;/p&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p align=&quot;left&quot;&gt;Fluoride is released to environment naturally and via Industrial  effluents. According to concentration of fluoride in potable water and its total uptake rate, can be&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;beneficial or harmful. Due to simplicity of operation, easy access to the coagulants of alum and poly aluminum chloride and low cost, coagulation was selected for fluoride removal from water. The purpose of this study was to comparison the efficiency of alum and commercial poly&lt;/p&gt;&lt;p&gt;aluminum chloride for fluoride removal from water.&lt;/p&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p&gt;&lt;strong&gt;Methods&lt;/strong&gt;&lt;/p&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p align=&quot;left&quot;&gt;Lab scale experiments were carried out via Jar apparatus. Variations of this study, including pH, coagulant dosage and fluoride concentration were experimented in defined conditions.&lt;/p&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p&gt;&lt;strong&gt;Results&lt;/strong&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;/font&gt;&lt;p&gt;&lt;/p&gt;&lt;/p&gt;&lt;p align=&quot;left&quot;&gt;Results indicate that optimum pH for both of coagulants was equal to 4. Concentrations of alum and poly Aluminum chloride for fluoride removal were 240 and 160 mg/L  respectively and removal efficiency in optimum pH and dosage of coagulant were 84.2 and 84 % respectively.&lt;/p&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;&lt;/p&gt;&lt;font face=&quot;Times New Roman&quot;&gt;&lt;p align=&quot;left&quot;&gt;According to data obtained from this study, it can be stated that coagulation is a suitable method for removal of fluoride from water and poly Aluminum chloride is compatible with alum.&lt;/p&gt;&lt;/font&gt;&lt;/font&gt;&lt;/font&gt;&lt;/font&gt;&lt;/font&gt;&lt;/font&gt;&lt;/font&gt;</abstract>
	<keyword_fa>فلوراید، انعقاد، آلوم، پلی‌آلومینیوم‌کلراید </keyword_fa>
	<keyword>fluoride, coagulation, alum, poly aluminum chloride</keyword>
	<start_page>55</start_page>
	<end_page>61</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-3-63&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>R.</first_name>
	<middle_name></middle_name>
	<last_name>Kalantary</last_name>
	<suffix></suffix>
	<first_name_fa>روشنک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رضایی کلانتری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>roshanak_rezaeikalantari@yahoo.com</email>
	<code>1360031947532846003810</code>
	<orcid>1360031947532846003810</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>School of Health, Iran University of</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S.</first_name>
	<middle_name></middle_name>
	<last_name>Jorfi</last_name>
	<suffix></suffix>
	<first_name_fa>سهند</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جوقی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1360031947532846003811</code>
	<orcid>1360031947532846003811</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health, Tarbiat Modares University,</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Esrafili</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اسرافیلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1360031947532846003812</code>
	<orcid>1360031947532846003812</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Ameri</last_name>
	<suffix></suffix>
	<first_name_fa>احمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عامری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1360031947532846003813</code>
	<orcid>1360031947532846003813</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>School of Health, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>R.</first_name>
	<middle_name></middle_name>
	<last_name>Baradar Niazi</last_name>
	<suffix></suffix>
	<first_name_fa>رقیه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>برادر نیازی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1360031947532846003814</code>
	<orcid>1360031947532846003814</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Environment Department, School of Health, Iran University of Medical</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Ameli</last_name>
	<suffix></suffix>
	<first_name_fa>آریان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عاملی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1360031947532846003815</code>
	<orcid>1360031947532846003815</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Environment Department, School of Health, Iran University of Medical</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
