<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>22</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر طراحی سایبان های افقی در قسمت بیرونی پنجره بر صرفه جویی در مصرف انرژی یک ساختمان اداری</title_fa>
	<title>The influences of horizontal external window shading on energy savings in the office building</title>
	<subject_fa>عوامل فیزیکی محیط کار</subject_fa>
	<subject>Physical agents at work</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;br&gt;
&lt;span style=&quot;color:#000000;&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;زمینه و اهداف&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; بیش از &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;۴۰&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; درصد از انرژی مصرفی جهان به ساختمان&#8204;ها اختصاص دارد که سهم قابل توجهی در تولید دی&#8204;اکسید کربن ایفا می&#8204;کند. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;پنجره&#8204;ها نقش مهمی در تبادل حرارتی بین محیط&#8204;های داخلی و خارجی ایفا می&#8204;کنند و &lt;/span&gt;&lt;span style=&quot;background:yellow&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;سایبان&#8204;های&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; خارجی می&#8204;توانند تأثیر قابل توجهی در انتقال حرارت ساختمان&#8204;ها داشته باشند. این مطالعه تأثیر سایبان خارجی افقی بر صرفه&#8204;جویی انرژی در ساختمان&#8204;ها را بررسی می&#8204;کند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&quot;B Nazanin&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:yellow&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;مواد و روش&#8204;ها: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:yellow&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;در این مطالعه، سایبان خارجی به صورت تیغه&#8204;های افقی عمود بر سطح پنجره&#8204;ها برای یک ساختمان اداری-تجاری ۱۰ طبقه در تهران طراحی و مدلسازی شد. تیغه&#8204;ها به&#8204;گونه&#8204;ای طراحی شدند که سایه ایجادشده توسط آن&#8204;ها سطح پنجره&#8204;ها را به&#8204;طور کامل پوشش دهد. تمرکز طراحی بر روز اول مرداد، به&#8204;عنوان گرم&#8204;ترین روز سال با بیشترین میزان تابش مستقیم خورشید بر سطح پنجره&#8204;ها، قرار داشت. تأثیر سایبان خارجی طراحی&#8204;شده بر بار سرمایشی ساختمان مورد مطالعه با استفاده از نرم&#8204;افزار &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:yellow&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;Carrier HAP&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:yellow&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; مورد بررسی قرار گرفت.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;نتایج: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;نتایج این مطالعه نشان داد که برای پنجره&#8204;های شرقی و غربی، &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;۱۵&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; تیغه افقی سایه&#8204;انداز، برای پنجره&#8204;های شمالی &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;۸&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; تیغه و برای پنجره&#8204;های جنوبی &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;۳&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; تیغه مورد نیاز است&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; همچنین مطابق نتایج، پنجره&#8204;های شرقی و غربی بیشترین تأثیر را بر بار سرمایشی ساختمان در صبح و بعد از ظهر دارند. استفاده از سایبان پیشنهادی باعث کاهش بار سرمایشی به میزان &lt;/span&gt;&lt;span style=&quot;background:yellow&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;23/9%، 33/11% و 37/16&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;% در ماه&#8204;های تیر، مرداد و شهریور شد. &lt;/span&gt;&lt;span style=&quot;background:lime&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;کاهش در هزینه برق مصرفی به دنبال کاهش بار سرمایشی ناشی از نصب تیغه&#8204;های سایبان بر روی پنجره&#8204;های ساختمان مورد مطالعه معادل 108 دلار (سال 1403) برآورد&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; شد. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt;نتیجه&#8204;گیری:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span style=&quot;background-color:#ffffff;&quot;&gt; استفاده از سایبان در قسمت بیرونی پنجره&#8204;ها عملکرد مطلوبی را از نظر صرفه&#8204;جویی در انرژی، آسایش حرارتی و بهبود جنبه&#8204;های زیبایی&#8204;شناختی ارائه می&#8204;دهند. انجام تحقیقات مشابه بر روی اشکال مختلف سازه&#8204;های سایبان در این زمینه سودمند به نظر می&#8204;رسد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Background and Aims: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Buildings consume more than 40% of global energy, significantly contributing to carbon dioxide emissions. Windows play a key role in heat exchange between indoor and outdoor environments, and external shading can notably impact building heat transfer. This study investigates the effect of horizontal external shading on energy savings in buildings.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Materials and Methods: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;In this study, external shading was designed and modeled in the form of horizontal blades perpendicular to the window surfaces for a 10-story office-commercial building in Tehran. The blades were designed such that the resulting shadow would fully cover the window surfaces, with a focus on August 1st (the hottest day of the year) when the highest direct solar radiation hits the window surfaces. The effect of the designed external shading on the building&amp;rsquo;s cooling load was evaluated using the Carrier HAP software.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Results: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;The results indicated that the eastern and western windows have the most significant impact on the building&amp;#39;s cooling load in the morning and afternoon, respectively. The proposed shading reduced the cooling load demand by 9.23%, 11.33%, and 16.37% in July, August, and September, respectively. This led to an electricity cost saving of 108 US dollars during the period. Implementing this shading in a megacity like Tehran could result in substantial energy savings during the summer and enhance thermal comfort.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;Conclusion: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;External shading systems effectively contribute to energy savings, improved thermal comfort, and aesthetic goals. Further research on various shading structures would be beneficial in this context.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>سایبان, آسایش حرارتی, صرفه جویی در مصرف انرژی, بار سرمایشی</keyword_fa>
	<keyword>shading, thermal comfort, energy savings, cooling load</keyword>
	<start_page>240</start_page>
	<end_page>256</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-4300-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Athena</first_name>
	<middle_name></middle_name>
	<last_name>Rafieepour</last_name>
	<suffix></suffix>
	<first_name_fa>آتنا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رفیعی‌پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>arp_63@yahoo.com</email>
	<code>13600319475328460046018</code>
	<orcid>13600319475328460046018</orcid>
	<coreauthor>No</coreauthor>
	<affiliation> Occupational Health Research Center, Department of Occupational Health, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>مرکز تحقیقات بهداشت کار، دپارتمان بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hasan</first_name>
	<middle_name></middle_name>
	<last_name>Irvani</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ایروانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>irvanih91@gmail.com</email>
	<code>13600319475328460046019</code>
	<orcid>13600319475328460046019</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Health Engineering and Safety, Damghan School of Health, Semnan University of Medical Sciences, Semnan, Iran</affiliation>
	<affiliation_fa>دپارتمان مهندسی بهداشت حرفه ای و ایمنی، دانشکده بهداشت دامغان، دانشگاه علوم پزشکی سمنان، سمنان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hamidreza</first_name>
	<middle_name></middle_name>
	<last_name>Jafari Nodoushan</last_name>
	<suffix></suffix>
	<first_name_fa>حمیدرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفری ندوشن</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hrjn.80@gmail.com</email>
	<code>13600319475328460046020</code>
	<orcid>0009-0007-2225-473X</orcid>
	<coreauthor>No</coreauthor>
	<affiliation> Student Research Committee, Department of Occupational Health and Safety Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>کمیته تحقیقات دانشجویی، دپارتمان بهداشت حرفه ای و ایمنی کار، دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Javad</first_name>
	<middle_name></middle_name>
	<last_name>Jafari</last_name>
	<suffix></suffix>
	<first_name_fa>محمدجواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>M_jafari@sbmu.ac.ir</email>
	<code>13600319475328460046021</code>
	<orcid>13600319475328460046021</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Health and Safety Engineering, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دپارتمان بهداشت حرفه ای و ایمنی کار، دانشکده بهداشت، دانشگاه علوم پزشکی شهید بهشتی، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Iraj</first_name>
	<middle_name></middle_name>
	<last_name>Alimohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علی‌محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>irajrastin1@gmail.com</email>
	<code>13600319475328460046022</code>
	<orcid>13600319475328460046022</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Occupational Health Research Center, Department of Occupational Health, School of Public Health, Iran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>مرکز تحقیقات بهداشت کار، دپارتمان بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Saber</first_name>
	<middle_name></middle_name>
	<last_name>Moradi Hanifi</last_name>
	<suffix></suffix>
	<first_name_fa>صابر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مرادی حنیفی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sabermoradi22@yahoo.com</email>
	<code>13600319475328460046023</code>
	<orcid>13600319475328460046023</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>ccupational Health Research Center, Department of Occupational Health, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>مرکز تحقیقات بهداشت کار، دپارتمان بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Javad</first_name>
	<middle_name></middle_name>
	<last_name>Afshari</last_name>
	<suffix></suffix>
	<first_name_fa>محمدجواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>افشاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohammad.j.afshari13@gmail.com</email>
	<code>13600319475328460046024</code>
	<orcid>0009-0000-7034-8078</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation> Air Pollution Research Center, Department of Occupational Health,  School of Public Health, Iran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>مرکز تحقیقات آلودگی هوا، دپارتمان بهداشت حرفه ای، دانشکده بهداشت، دانشگاه علوم پزشکی ایران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
