<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iran Occupational Health Journal</title>
<title_fa>سلامت كار ايران</title_fa>
<short_title>ioh</short_title>
<subject>Medical Sciences</subject>
<web_url>http://ioh.iums.ac.ir</web_url>
<journal_hbi_system_id>136</journal_hbi_system_id>
<journal_hbi_system_user>journal136</journal_hbi_system_user>
<journal_id_issn>1735-5133</journal_id_issn>
<journal_id_issn_online>2228-7493</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/ioh</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>کاربرد SPME به عنوان یک نمونه بردار غیر فعال در ارزیابی تماس های استنشاقی-مطالعه موردی بر روی 2-کلروفنول</title_fa>
	<title>Application of SPME as a passive air sampler for inhalation exposure assessment: a case study on 2-Chlorophenol</title>
	<subject_fa>پایش آلودگی هوا</subject_fa>
	<subject>Air pollution monitoring</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;  &lt;strong&gt;زمینه و هدف:&lt;/strong&gt;ترکیبات هیدروکربنی هالوژنه یکی از گروه ­ های بزرگ آلاینده ­ های هوا بوده و تکنیک­های متعددی جهت پایش تماس­های محیطی و شغلی با آنها ارائه شده است. در این پژوهش کاربرد روش استخراج میکرونی از فاز جامد به عنوان یک روش عاری از حلال در نمونه برداری از 2- کلروفنول مورد بررسی قرار گرفته است. &lt;/p&gt;&lt;p&gt;  &lt;strong&gt;روش بررسی :&lt;/strong&gt;غلظت­های مختلف 2-کلروفنول در یک سیستم دینامیک تولید اتمسفر استانداد ساخته شد و تاثیر پارامتر­های مختلف نمونه برداری شامل نوع فیبر، حالت کالیبراسیون و طول در سوزن بر روی عملکرد SPME بررسی قرار گرفت. نرخ نمونه­برداری واقعی بر اساس نمونه برداری هم­زمان تعیین گردید و در محاسبات مورد استفاده قرار گرفت تاثیر پارامتر­های محیطی شامل درجه حرارت، سرعت، دما و همچنین زمان نگهداری بر روی عملکرد نمونه­بردار بررسی گردید. &lt;/p&gt;&lt;p&gt;  &lt;strong&gt;یافته ها:&lt;/strong&gt; نتایج نشان داد که دما و سرعت در حالت دینامیک تاثیر معنی­داری بر روی نرخ نمونه­برداری ندارند. هر چند رطوبت می­تواند به عنوان فاکتوری موثر در تعیین مقدار این ترکیب مداخله نماید. نتایج نشان داد که نگهداری نمونه در فیبر CAR/PDMS وابسته به دما بوده و با کاهش دما، قابلیت نگهداری آن افزایش می­یابد. هر چند حتی در شرایط با دمای پایین نیز نگهداری بیش از 3 روز توصیه نمی­گردد. &lt;/p&gt;&lt;p&gt;  &lt;strong&gt;نتیجه گیری:&lt;/strong&gt; استفاده از فیبر CAR/PDMS در سوزن میتواند به طور قابل قبولی در ارزیابی 2- کلروفنول در هوا مورد استفاده قرار گیرد. عدم تاثیر پذیری نرخ نمونه­برداری در دامنه گسترده دمایی و سرعت جریان هوا، این شیوه را به گزینه مناسبی برای بررسی تماس با عوامل زیان آور شیمیایی در جامعه و محیط­های­ کاری می­نماید. &lt;/p&gt;</abstract_fa>
	<abstract>&lt;p&gt;  Background and aims: Halogeneated hydrocarbons are among the most important classes of toxic chemicals considering environmental and occupational health which can be quantified by several methods. This study examined the applicability of solid phase microextraction for sampling and quantifying of 2-Chlorophenol in the air. &lt;/p&gt;&lt;p&gt;  Methods:A dynamic standard atmosphere generation system was constructed and effects of sampling parameters such as fiber type, calibration mode and retraction length on sampler performance were studied. Actual sampling rate calculated according to side-by-side sampling was used for quantifications. The effects of environmental parameters including temperature, humidity, and air velocity, were studied. &lt;/p&gt;&lt;p&gt;  Results:There was no significant difference among sampling rates at different temperatures and velocities (in dynamic conditions) but relative humidity had a significant negative effect on the sampling rate. Storage ability of the SPME samples were seriously depends on the time and temperature of storage. The SPME samples had a poor storage capacity in comparison with the charcoal samples. However, sample recovery increased with decreasing the storage temperature. &lt;/p&gt;&lt;p&gt;  Conclusion:CAR/PDMS SPME in retracted mode is a good alternative for sampling and analysis of this class of compounds in the air. Its sampling rate is stable in wide range of temperatures and velocities. Therefore, it can be used readily in environmental and occupational exposure assessments. &lt;/p&gt;</abstract>
	<keyword_fa>نمونه برداری از هوا, نمونه بردار غیرفعال, استخراجی فاز میکرونی جامد, 2-کلروفنول, ارزیابی تماس</keyword_fa>
	<keyword>Air sampling, Passive sampler, SPME, 2-Chlorophenol, Exposure assessment</keyword>
	<start_page>35</start_page>
	<end_page>44</end_page>
	<web_url>http://ioh.iums.ac.ir/browse.php?a_code=A-10-515-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Javad</first_name>
	<middle_name></middle_name>
	<last_name>Zare Sakhvidi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد جواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زارع سخویدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mjzs63@gmail.com</email>
	<code>13600319475328460014669</code>
	<orcid>13600319475328460014669</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Yazd University of Medical Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی شهید صدوقی یزد</affiliation_fa>
	 </author>


	<author>
	<first_name>AbdulRahman</first_name>
	<middle_name></middle_name>
	<last_name>Bahrami</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالرحمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهرامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Bahrami@ umsha.ac.ir</email>
	<code>13600319475328460014670</code>
	<orcid>13600319475328460014670</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Hamedan University of Medical Science</affiliation>
	<affiliation_fa>انشگاه علوم پزشکی وخدمات بهداشتی درمانی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Alireza</first_name>
	<middle_name></middle_name>
	<last_name>Ghiasvand</last_name>
	<suffix></suffix>
	<first_name_fa>علیرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>غیاثوند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>arghiasvand@gmail.com</email>
	<code>13600319475328460014671</code>
	<orcid>13600319475328460014671</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Lorestan University</affiliation>
	<affiliation_fa>دانشگاه لرستان</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Mahjub</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محجوب</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mahjub@umsha.ac.ir</email>
	<code>13600319475328460014672</code>
	<orcid>13600319475328460014672</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Hamedan University of Medical Science</affiliation>
	<affiliation_fa>انشگاه علوم پزشکی وخدمات بهداشتی درمانی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Ludovic</first_name>
	<middle_name></middle_name>
	<last_name>Tuduri</last_name>
	<suffix></suffix>
	<first_name_fa>لودویک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>تودوری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ludovic.tuduri@irsst.qc.ca</email>
	<code>13600319475328460014673</code>
	<orcid>13600319475328460014673</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Institut des Sciences Moléculaires</affiliation>
	<affiliation_fa>Institut des Sciences Moléculaires</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
