Volume 12, Issue 5 (2015)                   ioh 2015, 12(5): 1-9 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moridi P, Atabi F, Nouri J. Weighting and Prioritizing of Air Pollutant Filtration Technologies for Controlling NH3, PM and VOCs by Fuzzy TOPSIS Method . ioh 2015; 12 (5) :1-9
URL: http://ioh.iums.ac.ir/article-1-1416-en.html
, far-atabi@jamejam.net
Abstract:   (5346 Views)

Background and aims: Air pollution is one of the most important factors in conflict with environmental quality in many cities around the world that can have negative effects on human health. Emission control from industrial and domestic sources in line with the objectives of sustainable development is an important and challenging problem. Decision making with regard to various indices of social, economic, and operational, is complicated. The aim of the present study are weighting , prioritization and selection of appropriate filtration technology with consideration of technical aspects, economic, high performance and low uncertainty.

 Methods: In this study a fuzzy TOPSIS method was used for weighting and ranking of air pollutant filtration technologies. Five research criteria were included: efficiency, cost, maintenance, design and size. This five criteria were considered for ranking of air pollutant filtration technologies related toNH3, PM, and VOCs.

 Results: According to the results HEPA filters with coefficient of 0.923 were identified as the most appropriate filtration technology for the particles in the petrochemical industry. Chemical absorption with coefficient of 867/0 for controlling particulate matter and plasma chemical technology with coefficient of 9586/0 for controlling VOCs were identified as the best technology.

 Conclusion: TOPSIS is one of the most reliable scientific and managerial methods of decision-making. In this study selecting the appropriate filtration technology for air pollutants including NH3, PPM, VOCs was addressed by using TOPSIS fuzzy method.

Full-Text [PDF 625 kb]   (2042 Downloads)    
Type of Study: Applicable | Subject: Air pollution
Received: 2015/01/4 | Accepted: 2015/07/26 | Published: 2015/10/4

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Iran Occupational Health

Designed & Developed by : Yektaweb