Volume 13, Issue 5 (2016)                   ioh 2016, 13(5): 11-23 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farhang Dehghan S, Golbabaei F, Maddah B, Yarahmadi R, Sadigh Zadeh A. Fabrication and Optimization of Electrospun Polyacrylonitrile Nanofiber for Application in Air Filtration. ioh 2016; 13 (5) :11-23
URL: http://ioh.iums.ac.ir/article-1-1538-en.html
Tehran University of Medical Sciences , fgolbabaei@sina.tums.ac.ir
Abstract:   (7079 Views)

Background and aims: In nanofibrous filters, morphological properties, diameter of fibers and porosity percent of media are the most filtration characteristics. Therefore, the present study aimed to optimize the electrospinning parameters for reaching to the desired values of the mentioned filter characteristics.

Method: For this purpose, a study design was prepared using response surface methodology (RSM), in which electrospinning factors such as solution concentration, applied voltage and electrospinning distance were considered input variables and the fiber diameter, porosity, bead number and average bead diameter to average fiber diameter (ABD/AFD) ratio were considered the output variables. Morphological features of fibers and porosity of media were done through image processing approach of Scanning Emission Microscopy (SEM) images.

Results: Maximum concentration in assessed range can provide the best morphology and also the maximum diameter. The highest correlation coefficient has been seen between fiber diameter and solution concentration (p <0.05, r=0.73). Porosity and applied voltage represent the strongest relationship (p >0.05, r=0.39).  There was the significant relationship between both concentration and electrospinning distance and bead size (r=-1.6, r=0.56, respectively). Bead number was decreased specially with increase in concentration.

Conclusion: Totally, RSM could well determine the relationship between input and response variables. High regression coefficient in mathematical models indicated the importance of the experimental values. The validation test shown the experimental data are in good agreement with the predicted ones.

Full-Text [PDF 1061 kb]   (3769 Downloads)    
Type of Study: Research | Subject: New air purification technologies (nano and plasma)
Received: 2015/06/21 | Accepted: 2016/01/17 | Published: 2016/12/31