Background and aims: Nowadayes, air pollution is considered as one of the most important problems of urbanization and industrial life and all members of the society is affected by this problem. Cement industry is one of the key industries in developing countries, which is widely applied in various projects. However, the industry is considered one of the industry's environmental pollutants. In this study, environmental pollution of Kerman Cement Factory, which is located on the western border of the city of Kerman has been studied.
Methods: For this purpose, photometer instrument DUST TRAK and Method BS-EN-12341 are used to determine the amount of suspended PM2.5 and PM10 of Ambient air at the four sides of the factory To determine the aerosol outlet Flue gas monitoring system based on EPA Metho 2 was used and the amount of exhaust gas molecular weight was calculated.To evaluation the concentration of exhaust gases of combustion from the furnace electro Number 1, 2 and 3 by device OPTIMA7 Samples were taken. Also, this study has been carried out from 1389 to 1392.
Results: The results show that the maximum concentration of suspended particles PM2.5 and PM10 from the south side - near the entrance of the year 1389, East side - opposite the depot clinker year1391 and the west side - opposite to mine raw materials in 1389 year That is exceeded.
Conclusion: associated with emission of Flue and environmental dust can be said that the concentration of dust in some years about standards is over, But the total concentrations of output and environmental dust can be acceptable, especially in the 92 years evaluated.
Rights and permissions | |
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. |